Where PhDs and companies meet
Menu
Login

AutoF_Cartographie électro-anatomique en électrophysiologie interventionnelle pour le traitement des arythmies ventriculaires complexes // AutoF_Electroanatomical mapping in interventional electrophysiology for the treatment of complex ventricular arrhyth

ABG-132878
ADUM-66710
Thesis topic
2025-07-12
Université de Lorraine
VANDOEUVRE - Grand Est - France
AutoF_Cartographie électro-anatomique en électrophysiologie interventionnelle pour le traitement des arythmies ventriculaires complexes // AutoF_Electroanatomical mapping in interventional electrophysiology for the treatment of complex ventricular arrhyth
Electrophysiologie cardiaque interventionnelle, Traitement du signal et de l'image
Interventional cardiac electrophysiology, Signal and image processing

Topic description

Le projet de thèse vise à valider des modules qui pourront être intégrés au système de cartographie cardiaque Carto 3 puis utilisés par des cardiologues rythmologues pour traiter des patients atteints de tachycardies ventriculaires. Lors de procédures interventionnelles, des cartes électro-anatomiques sont réalisées chez ces patients afin de localiser, puis ablater à l'aide de radiofréquence, l'isthme critique responsable de la tachycardie ventriculaire. Plusieurs méthodes de cartographie et stratégies d'ablation sont utilisées lors de ces procédures, mais présentent de nombreuses contraintes. Le patient doit être en tachycardie au moment de l'examen (pour la cartographier ou obtenir un tracé ECG de référence), or ces tachycardies peuvent ne pas se déclencher le jour de l'examen, se déclencher et être mal tolérées par le patient (syncope, nécessité de recourir à un choc électrique pour l'arrêter, dégénérescence du rythme en fibrillation ventriculaire) ... Ces procédures peuvent être longues, contraignantes, et éprouvantes pour les patients. De nouvelles méthodes visent donc à mieux identifier ces isthmes critiques, de façon plus précise, moins contraignante et plus rapide, durant et avant la procédure d'ablation.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------------------------

This thesis aims to validate modules that will further be integrated into the Carto 3 cardiac 3D mapping system. These modules could then be used by electrophysiologists to treat patients with ventricular tachycardia. During interventional procedures, electro-anatomical maps of the patient's ventricle are created to locate and then ablate, using radiofrequency, the critical isthmus responsible for the ventricular tachycardia. Several mapping methods and ablation strategies are used during these procedures, but they present numerous constraints. The patient must be in ventricular tachycardia during examination (to map it or obtain a reference ECG morphology); however, these tachycardias may not occur on the day of the examination, may occur and be poorly tolerated by the patient (syncope, need for an electrical shock to stop it, degeneration of the rhythm into ventricular fibrillation). These procedures can be long, demanding, and challenging for patients. Therefore, new methods aim to better identify these critical isthmuses faster, more effectively, and more precisely, during, and before the ablation procedure.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Début de la thèse : 01/10/2025

Funding category

Funding further details

En emploi à titre principal

Presentation of host institution and host laboratory

Université de Lorraine

Institution awarding doctoral degree

Université de Lorraine

Graduate school

266 BioSE - Biologie Santé Environnement

Candidate's profile

• Formation : M2 ou ingénieur dans une des disciplines suivantes : sciences de l'ingénieur, ingénierie biomédicale, physique, mathématiques, sciences des données et recherche clinique. Une expérience (stage M2) dans le domaine de l'électrophysiologie cardiaque est un plus. • Curieux, autonome, dynamique, présentant un vif intérêt pour la recherche et l'électrophysiologie cardiaque. • Bonne maîtrise de l'anglais, des statistiques et des outils de programmation scientifique (notamment Matlab). Bonnes capacités de communication.
- Training: MSc degree or equivalent in one of the following disciplines: engineering sciences, biomedical engineering, physics, mathematics, data sciences and clinical research. Experience (MSc internship) in cardiac electrophysiology is a plus. - Curious, autonomous, dynamic, with a keen interest in research and cardiac electrophysiology. - Good command of English, statistics and scientific programming tools (Matlab in particular). Good communication skills.
2029-09-30
Partager via
Apply
Close

Vous avez déjà un compte ?

Nouvel utilisateur ?